ICOMP, ICOM Next Connection problem with ISTA
08-09-2019, 17:59 PM,
Post: #31
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
; or # must be on obd, not on remote!
|
|||
08-09-2019, 18:04 PM,
Post: #32
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
|
|||
08-09-2019, 19:02 PM,
Post: #33
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
What is the path of ediabas.ini you have edited?
|
|||
08-09-2019, 19:31 PM,
Post: #34
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
|
|||
08-09-2019, 19:32 PM,
Post: #35
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
Stupid question: Is your firewall dissabled?
|
|||
08-09-2019, 20:04 PM,
Post: #36
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
|
|||
10-09-2019, 16:29 PM,
Post: #37
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
Hello,
with ISTA VCI Ediabas and Ediabas.ini ;Interface = REMOTE was Ediabas on (Free) and message mit ICOM schould update then coming always Error: IHF-0028 ILLEGAL IFH VERSION EDIABAS - ERROR REFERENCE IFH-0028: ILLEGAL IFH VERSION EDIABAS_IFH_0028 Meaning: A wrong Interface Handler version is installed. Causes: Your EDIABAS requires a different Interface Handler version than that which is installed. Error correction: Re-install the required EDIABAS version and possibly the Extension Disk. Re-install the required EDIC API or ADS version, respectively. any idea whats happen and how can fix it? thanks |
|||
15-09-2019, 20:35 PM,
Post: #38
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
Because it's not REMOTE... but RPLUS
Only way to use is ediabas rplus configuration i can help you in teamviewer now for free |
|||
15-09-2019, 22:20 PM,
Post: #39
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
two options on RPLUS
1) EDIABAS.ini configuration Interface= RPLUS [TCP] ;========================================== RemoteHost = (IP ICOMP from itoolradar) Port = 6801 TimeoutConnect = 2000 TimeoutReceive = 2000 TimeoutFunction = 10000 ; TimeResponsePending = 5000 ; DisconnectOnApiEnd = 1 ; InitCmd0 = FE,04,00,03,01 ; InitCmd1 = FD,05,00,03,01 2) Ediabas.ini configuraton INTERFACE= RPLUS:ICOM_P RPLUS.ini configuration [ICOM] VINPATH = \\smucXXXX.muc\icomp_files$ VINPATH2 = \\smucXXXX.muc\icomp_files2$ VINTimeout = 5000 [ICOM_P] REMOTEHOST = ............ ( IP icomP from itoolradar) Port = 6801 ;Timeout wird bei erstem Verbindungsaufbau verwendet TimeoutConnect = 5000 ;Timeout wird ... TimeoutReceive = 5000 ;Timeout wird ...TF = TF + TR TimeoutFunction = 10000 DisconnectOnApiEnd = 1 [LAN] REMOTEHOST = 192.168.68.40 Port = 6801 TimeoutConnect = 5000 TimeoutReceive = 5000 TimeoutFunction = 10000 If my post helped you hit the thanks and reputation button!
|
|||
07-10-2019, 23:00 PM,
Post: #40
|
|||
|
|||
RE: ICOMP, ICOM Next Connection problem with ISTA
Is the ICOMP NEXT just meant for factory use or is it the newest version of ICOM dealer use?
|
|||